( New Zealand) +64 9 415 0404 |  info@watertest.co.nz

  • Acidity Test Kit

    Order Code 7182-01

    This kit measures for acidity by using the phenolphthalein endpoint to determine hydrochloric, sulfuric, and phosphoric acids. Range/sensitivity is 1 drop = 0.1 or 1.0% (as the particular acid).

  • Alkalinity Test Kit

    Order Code 4491-DR-01

    This Alkalinity Test Kits uses a dropper pipet with standard acid to the phenolphthalein (P) and/or total (T) alkalinity endpoint. Range and sensitivity is 1 drop = 10 ppm as CaCO3.

    50 Test / Kit

  • Aluminum Test Kit

    Order Code 3569-01

    This Aluminum test kit measures aluminum in water using the Octet Comparator. A pink to red color will form when aluminum reacts with Eriochrome Cyanine R, at pH 6. Range and sensitivity is 0 - 0.5 ppm Al3+.

    Test Type: Octet Comparator Range and Sensitivity 0, 0.1, 0.15, 0.2, 0.25, 0.3, 0.4, 0.5 ppm No. of tests 50

  • Phenolphthalein/Total Alkalinity Test Kit

    Order Code 4533-DR-01

    This Alkalinity Test Kit use titrations with standard acid to the phenolphthalein (P) and/or total (T) alkalinity endpoint. Range and sensitivity is 0-200 ppm/ 4 ppm as CaCO3.

    Test System:P & T Alkalinity Direct Reading Titrator Range Sensitivity: 0-200 ppm/4 ppm as CaCO3 No. of tests 50 at 200 ppm

  • Alkalinity Test Kit

    Order Code 4533-01

    This Alkalinity Test Kits uses a dropper pipet with standard acid to the phenolphthalein (P) and/or total (T) alkalinity endpoint. Range and sensitivity is 1 drop = 10 ppm as CaCO3.

    Test System: P & T Alkalinity Dropper Pipet Range Sensitivity: 1 drop = 10 ppm as CaCO3 No. of tests 50 at 200 ppm

  • Alkalinity in Water Test Kit

    Order Code 7240-02

    This kit tests for Alkalinity using the dropper bottle method. Range/sensitivity is 1 drop = 10, 25, or 50 ppm as CaCO3.

    Test System: P & T Alkalinity Dropper Bottle Range/Sensitivity: 1 drop = 10, 25, or 50 ppm as CaCO3 No. of tests: 100 at 500 ppm

  • Alkalinity Test Kit

    Order Code 3467-01

    This Alkalinity Test Kits uses a Direct Reading Titrator with standard acid to the phenolphthalein (P) and/or total (T) alkalinity endpoint. Range and sensitivity is 0–200 ppm as CaCO3 in 4 ppm increments.

    Test System: Direct Reading Titrator for P&T Alkalinity Range/Sensitivity: 0–200 ppm as CaCO3 in 4 ppm increments No. of tests: 50 at 200 ppm

  • Hydroxide, Phenolphthalein & Total Alkalinity Test Kit

    Order Code 7515-01

    This Alkalinity Test Kits uses a Dropper Pipet with standard acid to the phenolphthalein (P) and/or total (T) alkalinity endpoint. Where hydroxyl (OH) alkalinity is determined directly, the sample is pretreated with barium to precipitate carbonates. All results are expressed as CaCO3. Range and sensitivity is 1 drop = 10 ppm as CaCO3.

    Test System: P, T, & OH Alkalinity Dropper Pipet Range/Sensitivity: 1 drop = 10 ppm as CaCO3 No. of tests: 50 at 200 ppm

  • Ammonia Nitrogen Test Kit

    Order Code 3304-01

    In this Ammonia Nitrogen test kit, salicylate reacts to form a blue color and levels are determined using the Octet Comparator. Range and sensitivity is 0.0 - 2.0 ppm NH3-N.

    Test System: Salicylate Octa-Slide 2 Range/Sensitivity: 0.0, 0.05, 0.1, 0.25, 0.5, 1.0, 2.0 ppm NH3-N No. of tests: 50

  • Ammonia Nitrogen Colorimeter Test Kit

    Order Code 3680-01

    In this Ammonia Nitrogen colorimeter test kit, Nessler's reagent reacts with ammonia to form a yellow to brown color and levels are determined using a Colorimeter. Range and sensitivity is 0-5 ppm/0.05 ppm NH3-N.

    Test System: Nessler Colorimeter Range/Sensitivity: 0-5 ppm/0.05 ppm NH3-N No. of tests: 100

  • Arsenic Test Kit

    Order Code 4053-02

    This Arsenic testing procedure requires about 15 minutes and employs a test strip. Inorganic As+3 and As+5 are converted to arsine gas. This reacts with the test strip in a closed container and produces yellow to brown colors on the strip. The strip colors are compared to a color chart to determine the arsenic concentration in ppb.

    Test System: Arsenic Test Strip Range/Sensitivity: <4, 4, 8, 10, 12, 14, 16, 20, 25, 30, 50, 85, 100, 150, 175, 200, 300, 400 ppb No. of tests: 50

  • (BOD) Biochemical Oxygen Demand Test Kit

    Order Code 7420

    This is a determination of the amount of organic material in wastewater by measuring and comparing the dissolved oxygen content before and after incubating the sample for 5 days at 20°C. All reagents, including seed capsules and glassware needed to perform this test are included in the kit. Incubator and DO meter are not included.

    Test System: BOD Buret Titration Range/Sensitivity: 1 mL = 0.2 mg O2 0-1000 mg/L No. of tests: 100

  • BRICORR THPS Test Kit

    Order Code BRI-4-8776-01

    This test kit is used for the determination of Tetrakis Hydroxymethyl Phosphonium Sulfate (THPS) in BRICORR® THPS

    Test System: Direct Reading Titrator Range/Sensitivity: 0-100/2 ppm THPS No. of tests 60

  • Bromine Test Kit

    Order Code 6955-01

    This test kit measures for Bromine using DPD Tablets and the Octa-Slide 2 Comparator. Range/sensitivity is 0.2-3.0 ppm Br.

    Test System: DPD Tablet Octa-Slide 2 Comparator Range/Sensitivity: 0.2, 0.4, 0.6, 0.8, 1.0, 1.5, 2.0, 3.0 ppm Br) No. of tests 50

  • Bromine, Free Chlorine, and Total Chlorine Kit

    Order Code 6824-01

    This test kit measures for Residual Bromine, Free Chlorine, and Total Chlorine using DPD Tablets and the Octa-Slide 2 Comparator. Range/sensitivity is 0.2-3.0 ppm Br.

    Test System: DPD Tablet Bromine in Chlorine Octa-Slide 2 Comparator Range/Sensitivity: 0.2, 0.4, 0.6, 0.8, 1.0, 1.5, 2.0, 3.0 ppm Br No. of tests: 50

  • Bromine Colorimeter Test Kit

    Order Code 3672-01

    This test kit measures Bromine using DPD Tablets and the 1200 Colorimeter for Bromine DPD. Range and sensitivity is 0-7.0 ppm/0.05 ppm Br.

    Test System: DPD Tablet Colorimeter Range/Sensitivity: 0-7.0 ppm/0.05 ppm Br No. of tests: 100

  • DPD Free,Total & Combined Chlorine Test Kit

    Order Code 3308-01

    This Chlorine test kit measures free, total & combined Chlorine using Chlorine DPD tablets and the Octa-Slide 2 Comparator. Range/sensitivity is 0.2 - 3.0 ppm Cl.

    Test System: DPD Tablet Octa-Slide 2 Range/Sensitivity: 0.2, 0.4, 0.6, 0.8, 1.0, 1.5, 2.0, 3.0 ppm Cl No. of tests: 50

  • Chlorine in Drinking Water Test Kit

    Order Code 3312-01

    This Chlorine test kit measures Chlorine in drinking water using Chlorine DPD tablets and the Octa-Slide 2 Comparator. Range/sensitivity is 0.1 - 1.0 ppm Cl.

    Test System: DPD Tablet Octa-Slide 2 Range/Sensitivity: 0.1, 0.2, 0.3, 0.4, 0.5, 0.6, 0.8, 1.0 ppm Cl No. of tests: 50

  • Chlorine in Water Test Kit

    Order Code 3313-01

    This Chlorine test kit measures Chlorine in water using Chlorine DPD tablets and the Octa-Slide 2 Comparator. Range/sensitivity is 1.0 - 6.0 ppm Cl.

    Test System: DPD Tablet Octa-Slide 2 Range/Sensitivity: 1.0, 1.5, 2.0, 2.5, 3.0, 4.0, 5.0, 6.0 ppm Cl No. of tests: 50

  • Dual Range Chlorine Test Kit

    Order Code 3314-01

    This Dual Range Chlorine Test Kit tests for high and low ranges of chlorine using the Octa-Slide 2 Comparator. Low range: 0.1-1.0 ppm Cl. High range: 1.0-6.0 ppm Cl.

    Test System: DPD Tablet Octa-Slide 2 Comparator for Free & Total Range/Sensitivity: Low: 0.1-1.0 ppm Cl high: 1.0-6.0 ppm Cl No. of tests: 100

  • High Range Chlorine Test Kit

    Order Code 3328-01

    This Chlorine test kit measures for high ranges of Chlorine using Chlorine DPD tablets and the Octa-Slide 2 Comparator. Range/sensitivity is 1.0-10.0 ppm Cl.

    Test System: DPD Tablet Octa-Slide 2 Range/Sensitivity: 1.0, 2.0, 3.0, 4.0, 5.0, 6.0, 8.0, 10.0 ppm Cl No. of tests: 50

  • Chlorine DPD Tablet Colorimeter Test Kit

    Order Code 3670-01

    This test kit measures Chlorine levels using Chlorine DPD tablets and readings from the 1200 Colorimeter. Range/sensitivity is 0-4.0 ppm/0.05 ppm Cl.

    Test System: DPD Tablet Colorimeter Range/Sensitivity: 0-4.0 ppm/0.05 ppm Cl No. of tests: 100

  • Chlorine Liquid DPD Colorimeter Test Kit

    Order Code 3670-01-LI

    This test kit measures Chlorine levels using Chlorine DPD liquid and readings from the 1200 Colorimeter. Range/sensitivity is 0-4.0 ppm/0.05 ppm Cl.

    Test System: DPD Liquid Colorimeter Range/Sensitivity: 0-4.0 ppm/0.05 ppm Cl No. of tests: 144

  • Chlorine Test Kit

    Order Code 3176-02

    This Chlorine test kit measures for Chlorine using the direct reading titrator method. Range/sensitivity is 0-10 ppm/0.2 ppm Cl.

    Test System: Direct Reading Titrator Range/Sensitivity: 0-10 ppm/0.2 ppm Cll No. of tests: 50 at 10 ppm

  • Chlorine / Bromine Test Kit

    Order Code 3624-01

    This test kit measures for Chlorine or Bromine using the direct reading titrator method. Range/sensitivity is 0-10 ppm/0.2 ppm Cl or Br.

    Test System: Chlorine or Bromine Direct Reading Titrator Range/Sensitivity: 0-10 ppm/0.2 ppm Cl or Br No. of tests: 50 at 10 ppm

  • FAS-DPD Chlorine Test Kit

    Order Code 7514-01

    The DPD-FAS titration test kit measures Free and Total Chlorine in 0.2 ppm and 0.5 ppm increments. The distinct color change allows for accurate readings even at very low or high chlorine levels. The DipCell Color Comparator displays pH levels from 6.8 to 8.2 for 50 tests. The pH test is measured using liquid reagents.

  • DPD Chlorine Test Kit

    Order Code 3316-01

    This kit is used for testing water for Free Available Chlorine, Monochloramine, Dichloramine, and Total Residual Chlorine using DPD Tablets and the Octa-Slide 2 Comparator. Range and sensitivity is 0.2-3.0 ppm Cl.

    Test System: DPD Tablet Octa-Slide 2 Range/Sensitivity: 0.2, 0.4, 0.6, 0.8, 1.0, 1.5, 2.0, 3.0 ppm Cl No. of tests: 50

  • Chlorine - pH Test Kit

    Order Code 6980-01

    This kit is used for testing for Free Available Chlorine, Monochloramine, Dichloramine, Total Residual Chlorine, and pH using DPD Tablets, Phenol Red Tables and the Octa-Slide 2 Comparator. Range and sensitivity is Low: 0.1-1.0 ppm Cl, High: 1.0-6.0 ppm Cl, pH: 6.8-8.2.

    Test System: DPD Tablet/Phenol Red Tablet 3 Octet Comparators Range/Sensitivity: Low: 0.1-1.0 ppm Cl , High: 1.0-6.0 ppm Cl , pH: 6.8-8.2 No. of tests: 100

  • Chlorine Test Kit

    Order Code 4497-DR-01

    This test kit measures for high Chlorine levels using the direct reading titrator method. Range/sensitivity is 0-200 ppm/4 ppm Cl

    Test System: Direct Reading Titrator Range/Sensitivity: 0-200 ppm/4 ppm Cl No. of tests: 50 at 200 ppm

  • Chlorine Test Kit

    Order Code 4497-01

    This test kit measures for high Chlorine levels using the dropper pipet method. Range/sensitivity is 1 drop = 10 ppm Cl.

    Test System: Dropper Pipet Range/Sensitivity: 1 drop = 10 ppm Cl No. of tests: 50 at 200 ppm

  • Chlorine Test Kit

    Order Code 4501-01

    This test kit measures for Chlorine levels using the Dropper Pipet method. Range/sensitivity is 1 drop = 1 ppm Cl.

    Test System: Dropper Pipet Range/Sensitivity: 1 drop = 10 ppm Cl No. of tests: 50

  • Chlorine Bleach Test Kit

    Order Code 7105-03

    This test kit measures for Chlorine Bleach using the Direct Reading Titrator method. Range/sensitivity is 00-10%/0.2% Cl.

    Test System: Direct Reading Titrator Range/Sensitivity: 0-10%/0.2% Cl No. of tests: 50 at 10%

  • Chlorine Bleach Test Kit

    Order Code 7894-01

    This test kit measures for Chlorine Bleach using the Dropper Pipet method. Range/sensitivity is 1 drop = 0.005%, 0.05%, or 0.5% Cl.

    Test System: Dropper Pipet Range/Sensitivity: 1 drop = 0.005%, 0.05%, or 0.5% Cl No. of tests 50 at 0.1, 1.0, or 10%

  • Cadmium Test Kit

    Order Code 7839-01

    This test kit measures for Cadmium in water by using a dithizone extraction of cadmium which produces a pink to red color. Level are determined using the Octa-Slide 2 Comparator. Range/sensitivity is 0.1, 0.2, 0.3, 0.4, 0.5, 0.6, 0.8, 1.0 ppm Cd.

    Test System: Octa-Slide 2 Comparator Range/Sensitivity: 0.1, 0.2, 0.3, 0.4, 0.5, 0.6, 0.8, 1.0 ppm Cd No. of tests: 20

  • Calcium Hardness in Fresh or Salt Water Test Kit

    Order Code 3609-01

    This kit tests for Calcium Hardness in fresh or salt water. Includes inhibitors to eliminate metal interferences. All results are as CaCO3. Range/sensitivity is 0-200 ppm/4 ppm CaCO3, 0-2,500 ppm by dilution

    Test System: Fresh & Salt Water Hardness Direct Reading Titrator Range/Sensitivity: 0-200 ppm/4 ppm CaCO3 0-2,500 ppm by dilution No. of tests: 20

  • Total Hardness Test Kit

    Order Code 4482-DR-LI-01

    This kit tests for Total Hardness by using the Direct Reading Titrator Method. All results are as CaCO3. Range/sensitivity is 0-200 ppm/4ppm CaCO3.

    Test System: Total Hardness Direct Reading Titrator Range/Sensitivity: 0-200 ppm/4ppm CaCO3 No. of tests: 50 at 200 ppm

  • Total Hardness Test Kit

    Order Code 4482-LI-02

    This kit tests for Calcium and magnesium hardness by using the Dropper Bottle method. All results are as CaCO3. Range/sensitivity is 1 drop = 10 ppm or 1 gpg CaCO3.

    Test System: Total Hardness Dropper Bottle Range/Sensitivity: 1 drop = 10 ppm or 1 gpg CaCO3 No. of tests: 50 at 200 ppm or 20 gpg

  • Calcium, Magnesium & Total Hardness Test Kit

    Order Code 4824-LT-02

    This kit tests for Total, Calcium and magnesium hardness by using the Dropper Bottle method. All results are as CaCO3. Range/sensitivity is 1 drop = 10 ppm or 1 gpg CaCO3.

    Test System: Total Hardness Dropper Bottle Range/Sensitivity: 1 drop = 10 ppm or 1 gpg CaCO3 No. of tests: 50 at 200 ppm or 20 gpg

  • Calcium, Magnesium & Total Hardness Test Kit

    Order Code 4824-DR-LT-01

    This kit tests for Total, Calcium and magnesium hardness by using the Direct Reading Titrator method. All results are as CaCO3. Range/sensitivity is 0-200 ppm/4 ppm CaCO3.

    Test System: Calcium, Magnesium,& Total Hardness Direct Reading Titrator Range/Sensitivity: 0-200 ppm/4 ppm CaCO3No. of tests: 50 at 200 ppm or 20 gpg No. of tests: 50 at 200 ppm

  • Total Hardness in Water Test Kit

    Order Code 7171-02

    This kit tests for Total Hardness in water by using the Dropper Bottle Method. All results are as CaCO3. Range/sensitivity is 1 drop = 10, 25, or 50 ppm CaCO3.

    Test System: Total Hardness Dropper Bottle Range/Sensitivity: 1 drop = 10, 25, or 50 ppm CaCO3 No. of tests: 100

  • Total Hardness Test Kit

    Order Code 7246-02

    This kit tests for Total Hardness using the Dropper Bottle Method. All results are as CaCO3. Range/sensitivity is 1 drop = 2, 5, or 10 ppm CaCO3.

    Test System: Total Hardness Dropper Bottle Range/Sensitivity: 1 drop = 10, 25, or 50 ppm CaCO3 No. of tests: 100

  • Cadmium Test Kit

    Order Code 7839-01

    This test kit measures for Cadmium in water by using a dithizone extraction of cadmium which produces a pink to red color. Level are determined using the Octa-Slide 2 Comparator. Range/sensitivity is 0.1, 0.2, 0.3, 0.4, 0.5, 0.6, 0.8, 1.0 ppm Cd.

    Test System: Octa-Slide 2 Comparator Range/Sensitivity: 0.1, 0.2, 0.3, 0.4, 0.5, 0.6, 0.8, 1.0 ppm Cd No. of tests: 20

  • Chloride Test Kit

    Order Code 4503-DR-02

    This kit tests for Chloride in fresh water samples using the Direct Reading Titrator method.

    Water Type: Fresh Test System: Direct Reading Titrator Range/Sensitivity: 0-200 ppm Cl in 4.0 ppm increments No. of tests: 50

  • Total Coliform Test Kit for Drinking Water

    Order Code 4-3616

    The Coliform Indicator Test Kit utilizes an easy-to-use, disposable 5-tube method to indicate the presence of Total Coliform Bacteria in a drinking water supply. Coliform: 5 tubes, each containing a nutrient tablet, are reacted, stored at room temperature for 40-48 hours and examined for color change and gas formation. The number of positive tubes may be correlated to a MPN.

    Test System: Tableted nutrient based on 5 tube MPN Range/Sensitivity: Presence/Absence No. of tests: 1

  • Copper Test Kit

    Order Code 6616-01

    This copper test kit tests for copper using the LRC Comparator. Range and sensitivity is 0, 0.05, 0.10, 0.15, 0.20, 0.30, 0.40, 0.50 ppm Cu.

    Test System: LRC Comparator Range/Sensitivity: 0, 0.05, 0.10, 0.15, 0.20, 0.30, 0.40, 0.50 ppm Cu No. of tests: 50

  • Low Range Copper Test Kit

    Order Code 3619

    A simple color chart kit for measuring Copper from 0.05 to 1.0 ppm. Eight color standards are provided on the chart. Economical and easy-to-use.

    Low Range Copper Test Kit

  • Cyanide in Water Test Kit

    Order Code 7387-02

    Using the LaMotte Cyanide in Water Test Kit, the cyanide is first reacted with a chlorine donor to form cyanogen chloride, which then reacts with pyridine-barbituric acid to form a red-blue color. Levels are determined using the Octa-Slide 2 comparator.

    Test System: Octa-Slide 2 Comparator Range/Sensitivity: 0.0, 0.10, 0.15, 0.20, 0.25, 0.30, 0.35, 0.40 ppm Free CN- No. of tests: 50

  • DEHA Test Kit

    Order Code 4790-01

    This DEHA Test Kit tests for DEHA using the Octa-Slide 2 Comparator. Diethylhydroxylamine reacts with ferric iron to form ferrous iron, which is then measured by a standard iron test. Range and sensitivity is 0.05, 0.1, 0.2, 0.4, 0.6, 0.8, 1.0, 1.5 ppm DEHA

    Test System: Octa-Slide 2 Range/Sensitivity: 0.05, 0.1, 0.2, 0.4, 0.6, 0.8, 1.0, 1.5 ppm DEHA No. of tests: 100

  • Detergents Test Kit

    Order Code 4507-02

    Anionic surfactants are extracted with toluene and break up an ion pair, releasing bromphenol blue into a water layer. Using the drop count method, a standard color reagent is then used to determine the concentration. Range and sensitivity is 1 drop = 1.0 ppm Detergent.

    Test System: Drop Count Range/Sensitivity: 1 drop = 1.0 ppm Detergent No. of tests: 60 at 5.0 ppm

  • Dissolved Oxygen Test Kit

    Order Code 5860-01

    The LaMotte Dissolved Oxygen Test Kit tests for dissolved oxygen levels using the Direct Reading Titrator method. Range/sensitivity is 0-10 ppm/0.2 ppm O2.

    Test System: Direct Reading Titrator Range/Sensitivity: 0-10 ppm/0.2 ppm O2 No. of tests: 50 at 10 ppm

  • Fluoride Colorimeter Test Kit

    Order Code 3674-01

    This kit tests for fluoride using the DC1200 Colorimeter. Range and sensitivity is 0-2.0 ppm/0.03 ppm Fl-.

    Test System: Fluoride Colorimeter Test Kit Range/Sensitivity: 0-2.0 ppm/0.03 ppm Fl- No. of tests: 100

  • Formaldehyde in Water Test Kit

    Order Code 6701-01

    This kit tests for Formaldehyde in Water using the Octa-Slide 2 Comparator. Range and sensitivity is 0.0, 0.5, 1.0, 2.0, 4.0, 6.0, 8.0, 10.0 ppm Formaldehyde.

    Test System: Octa-Slide 2 Comparator Range/Sensitivity: 0.0, 0.5, 1.0, 2.0, 4.0, 6.0, 8.0, 10.0 ppm Formaldehyde No. of tests: 100

  • Glutaraldehyde Test Kit

    Order Code 7064-01

    This Glutaraldehyde Test Kit tests for glutaraldehyde using the Octa-Slide 2 Comparator. Range is 1 mL = 250 ppm glutaraldehyde with a 5 ppm sensitivity.

    Test System: Octa-Slide 2 Comparator Range/Sensitivity: 1 mL = 250 ppm Glutaraldehyde with a 5 ppm sensitivity No. of tests: 25

  • Hydrazine Test Kit

    Order Code 4850

    This Hydrazine Test Kit tests for hydrazine using the Octa-Slide 2 Comparator. Range and sensitivity is 0.00-0.50 ppm N2H4

    Test System: Octa-Slide 2 Comparator Range/Sensitivity: 0.00, 0.01, 0.05, 0.10, 0.20, 0.30, 0.40, 0.50 ppm N2H4 No. of tests: 50

  • Hydrogen Peroxide Test Kit

    Order Code 7138-DB-01

    This kit tests for Hydrogen Peroxide using the dropper bottle method. Range/Sensitivity is 1 drop = 5 ppm H2O2.

    Test System: Iodometric Dropper Bottle Range/Sensitivity: 1 drop = 5 ppm H2O2 No. of tests: 50

  • Hydrogen Peroxide Test Kit

    Order Code 7150-01

    This kit tests for Hydrogen Peroxide using the dropper bottle method. Range/Sensitivity is 1 drop = 0.5% H2O2

    Test System: Iodometric Dropper Bottle Range/Sensitivity: 1 drop = 0.5% H2O2 No. of tests: 50

  • Iodine Test Kit

    Order Code 7253-DR

    This kit tests for Iodine using the direct reading titrator method. Range/Sensitivity is 0-50 ppm/1 ppm I2.

    Test System: Direct Reading Titrator Range/Sensitivity: 0-50 ppm/1 ppm I2 No. of tests: 50 at 50 ppm

  • Iodine Test Kit

    Order Code 7253-01

    This Iodine Test Kit tests for iodine using the dropper pipet method. Range/Sensitivity is 0-50 ppm/1 ppm I2.

    Test System: Dropper Pipet Range/Sensitivity: 1 drop = 2.5 ppm No. of tests: 100 at 25 ppm

  • Low Iron in Water Test Kit

    Order Code 7787-01

    This kit tests for Low Iron in water using Iron Reagents and the LRC Comparator. Range/Sensitivity is 0.05, 0.10, 0.20, 0.30, 0.40, 0.60, 0.80, 1.0 ppm Fe.

    Test System: Total Iron LRC Comparator Range/Sensitivity: 0.05, 0.10, 0.20, 0.30, 0.40, 0.60, 0.80, 1.0 ppm Fe No. of tests: 30

  • Iron Test Kit

    Order Code 3347-01

    This kit tests for Iron using the Octa-Slide 2 Comparator. Range/Sensitivity is 0.5, 1.0, 2.0, 3.0, 4.0, 6.0, 8.0, 10.0 ppm Fe.

    Test System: Ferrous/Ferric Iron Octa-Slide 2 Comparator Range/Sensitivity: 0.5, 1.0, 2.0, 3.0, 4.0, 6.0, 8.0, 10.0 ppm Fe No. of tests: 50

  • Iron Colorimeter Test Kit

    Order Code 3681-01

    This kit tests for Iron using the 1200 Colorimeter for iron. Range/Sensitivity is 0-4.0 ppm/0.25 ppm Fe.

    Test System: Total Iron 1, 10 Phenanthroline Colorimeter Range/Sensitivity: 0-4.0 ppm/0.25 ppm Fe No. of tests: 100

  • Lead in Solder Test Kit

    Order Code 3582-01

    This kit is designed as a field spot test to identify suspect solders which is detected by the reaction of solder with acid and Sodium Rhodizonate.

    Test System: Spot Plate Plumbing Inspector Kit Range/Sensitivity: Yes/No No. of tests: 100

  • Low Range Manganese Test Kit

    Order Code 3588-02

    The Low Range Manganese test kit measures Manganese levels at 0.05, 0.1, 0.2, 0.4, 0.6, 0.8 and 1.0 ppm using the Octa-Slide 2 Comparator.

  • Manganese in Water Test Kit

    Order Code 7518

    This kit test for Manganese using the Octet Comparator. Range/sensitivity is 0.2, 0.4, 0.6, 0.8, 1.0, 1.4, 2.0, 3.0 ppm Mn. Required heat source not included.

    Test System: Persulfate Octet Comparator with Axial Reader Range/Sensitivity: 0.2, 0.4, 0.6, 0.8, 1.0, 1.4, 2.0, 3.0 ppm Mn (Requires heat source, not included) No. of tests: 50

  • Manganese Colorimeter Test Kit

    Order Code 3682-01

    This kit tests for manganese using the 1200 colorimeter for manganese. Range/sensitivity is 0-0.9 ppm/0.01 ppm Mn

    Test System: PAN Colorimeter Range/Sensitivity: 0-0.9 ppm/0.01 ppm Mn No. of tests: 100

  • High Range Molybdate Test Kit

    Order Code 3346-01

    This kit tests for Molybdate using Thioglycolate to form a yellowish color. Leves are measured using the Octa-Slide viewer. Range/sensitivity is 30, 60, 90, 120, 150, 180, 240, 300 ppm Molybdate.

    Test System: Thioglycolate, Molybdate Octa-Slide Range/Sensitivity: 30, 60, 90, 120, 150, 180, 240, 300 ppm Molybdate No. of tests: 50

  • Molybdenum in Water Test Kit

    Order Code 3160-01

    This kit tests for Molybdenum using Thioglycolate to form a yellowish color. Levels are measured using the Octa-Slide 2 Comparator. Range/sensitivity is 2, 5, 8, 10, 12, 15, 18, 20 ppm Molybdenum.

    Test System: Thioglycolate, Molybdenum Octa-Slide 2 Comparator Range/Sensitivity: 2, 5, 8, 10, 12, 15, 18, 20 ppm Molybdenum No. of tests: 50

  • Molybdenum Test Kit

    Order Code 3632-01

    This kit tests for Molybdenum the Dropper Pipet method. Range/sensitivity is 1 drop = 2 or 20 ppm Molybdenum.

    Test System: Molybdenum Dropper Pipet Range/Sensitivity: 1 drop = 2 or 20 ppm Molybdenum No. of tests: 50

  • Molybdenum Colorimeter Test Kit

    Order Code 3676-01

    This kit tests for Molybdenum using the 1200 colorimeter for Molybdenum. Range/sensitivity is 0.5-50 ppm/0.1 ppm Molybdenum.

    Test System: Thioglycolate Colorimeter Range/Sensitivity: 0.5-50 ppm/0.1 ppm Molybdenum No. of tests: 50

  • Low Range Molybdenum Test Kit

    Order Code 3628-01

    This kit tests for Molybdenum using the Test Strip method. Range/sensitivity is 0, 0.5, 1, 2, 5 ppm.

    Test System: Test Strip Range/Sensitivity: 0, 0.5, 1, 2, 5 ppm No. of tests: 50

  • Morpholine Test Kit

    Order Code 3133-01

    This kit tests for Morpholine in water using Naphthoquinone Sulfonic Acid to form a reddish color. Results are determined using the Octet Comparator. Range/sensitivity is 0, 1, 2, 4, 5, 6, 8, 10 ppm Morpholine.

    Test System: Octet Comparator Range/Sensitivity: 0, 1, 2, 4, 5, 6, 8, 10 ppm Morpholine No. of tests: 100

  • Nickel Test Kit

    Order Code 7802

    This kit tests for Nickel using Naphthoquinone Sulfonic Acid to form a reddish color. Results are determined using the Octet Comparator. Range/sensitivity is 0.5, 1.0, 2.0, 3.0, 4.0, 5.0, 7.5, 10.0 ppm Ni.

    Test System: Octet Comparator Range/Sensitivity: 0.5, 1.0, 2.0, 3.0, 4.0, 5.0, 7.5, 10.0 ppm Ni No. of tests: 20

  • Nitrate in Water Test Kit

    Order Code 3319

    This kit tests for Nitrate in water using reagents to form a pink color. Results are determined using the Octa-Slide 2 Comparator. Range/sensitivity is 0.25, 0.5, 1.0, 2.0, 4.0, 6.0, 8.0, 10.0 ppm NO3- -N.

    Test System: Octa-Slide 2 Comparator Range/Sensitivity: 0.25, 0.5, 1.0, 2.0, 4.0, 6.0, 8.0, 10.0 ppm NO3- -N No. of tests: 40

  • Nitrate & Phosphate in Water Test Kit

    Order Code 3119-01

    This kit tests for nitrate and phosphate in water using the LRC Comparator. Range/sensitivity is 0.2, 0.4, 0.6, 1.0 ppm NO3--N; 0.2, 0.4, 0.6, 1.0 ppm PO43-.

    Test System: Cadmium Reduction Nitrate/Phosphate LRC Comparator Range/Sensitivity: 0.2, 0.4, 0.6, 1.0 ppm NO3--N; 0.2, 0.4, 0.6, 1.0 ppm PO43 No. of tests: Nitrate: 40 (2) Phosphate: 50 (2)

  • Nitrate Nitrogen Test Kit

    Order Code 3615-01

    This kit tests for nitrate nitrogen using the LRC Comparator. Range/sensitivity is 0, 0.2, 0.4, 0.6, 0.8, 1.0 ppm NO3--N.

    Test System: Cadmium Reduction LRC Comparator Range/Sensitivity: 0, 0.2, 0.4, 0.6, 0.8, 1.0 ppm NO3--N No. of tests: 50

  • Nitrate/Nitrite Test Kit

    Order Code 3519-01

    This kit tests for nitrate or nitrite using the Octa-Slide 2 Comparator. Range/sensitivity is 0.25, 0.5, 1.0, 2.0, 4.0, 6.0, 8.0, 10.0 ppm NO3--N.

    Test System: Cadmium Reduction Octa-Slide 2 Comparator Range/Sensitivity: 0.25, 0.5, 1.0, 2.0, 4.0, 6.0, 8.0, 10.0 ppm NO3--N No. of tests: 40

  • Nitrate Nitrogen Tablet Test Kit

    Order Code 3354-01

    This kit tests for nitrate nitrogen using tablet reagents and the Octa-Slide 2 Comparator. Range/sensitivity is 0, 1, 2, 4, 6, 8, 10, 15 ppm NO3--N.

    Test System: Zinc Reduction Octa-Slide 2 Range/Sensitivity: 0, 1, 2, 4, 6, 8, 10, 15 ppm NO3--N No. of tests: 50

  • Nitrate Nitrogen Colorimeter Test Kit

    Order Code 3677-01

    This Nitrate Nitrogen Colorimeter Test Kit tests for nitrate nitrogen using the 1200 Colorimeter for nitrate nitrogen. Range/sensitivity is 0-3.0 ppm/0.05 ppm NO3--N.

    Test System: Cadmium Reduction Colorimeter Range/Sensitivity: 0-3.0 ppm/0.05 ppm NO3--N No. of tests: 50

  • Nitrite Test Kit

    Order Code 7101-DR-01

    This kit tests for nitrite using the direct reading titrator method. Range/sensitivity is 0-1000 ppm/20 ppm NaNO2.

    Test System: Permanganate Direct Reading Titrator Range/Sensitivity: 0-1000 ppm/20 ppm NaNO2 No. of tests: 50 at 1000 ppm

  • Nitrite in Water Test Kit

    Order Code 7101-01

    This kit tests for nitrite using the dropper pipet method. Range/sensitivity is 1 drop = 50 or 100 ppm NaNO2.

    Test System: Permanganate Dropper Pipet Range/Sensitivity: 1 drop = 50 or 100 ppm NaNO2 No. of tests: 50 at 1000 or 2000 ppm

  • Low Range Nitrite Drop Test Kit

    Order Code 7183-02

    This kit tests for low ranges of Nitrite using the Dropper Bottle method. Range/sensitivity is 1 drop = 50 ppm NaNO2.

    Test System: CAN Dropper Bottle Range/Sensitivity: 1 drop = 50 ppm NaNO2 No. of tests: 50 at 1000 ppm

  • Ozone in Water Test Kit

    Order Code 3526

    This kit tests for ozone in water using DPD reagents and the LRC Comparator. Range/sensitivity is 0.01, 0.03, 0.07, 0.11, 0.2, 0.4, 0.7, 1.0 ppm O3.

    Test System: DPD Tablet LRC Comparator Range/Sensitivity: 0.01, 0.03, 0.07, 0.11, 0.2, 0.4, 0.7, 1.0 ppm O3 No. of tests: 50

  • Ozone Colorimeter Test Kit

    Order Code 3678-01

    This Ozone Colorimeter kit tests for Ozone using the 1200 Colorimeter. Range/sensitivity is 0-0.4 ppm/0.04 ppm O3.

    Test System: Indigo Trisulfonate Colorimet Range/Sensitivity: 0-0.4 ppm/0.04 ppm O3 No. of tests: 100

  • Peracetic Acid Test Kit

    Order Code 7191-02

    This peracetic acid test kit tests for peracetic acid and hydrogen peroxide using the dropper bottle method. Range/sensitivity is 1 drop = 50 ppm peroxide and 1 drop = 15 ppm peracetic acid.

    Test System: Dropper Bottle Range/Sensitivity: 1 drop = 50 ppm Peroxide 1 drop = 15 ppm Peracetic Acid No. of tests: 50

  • pH Test Kit 6.0 - 7.4 pH

    Order Code 2109-01

    This kit tests for pH using the Octa-Slide 2 Comparator ranging from 6.0 - 7.4 pH.

    pH Indicator: Bromthymol Blue Octet Comparator Color Standard Values in pH Units: 6.0 6.2 6.4 6.6 6.8 7.0 7.2 7.4

  • pH Test Kit 6.8 - 8.2 pH

    Order Code 2110-01

    This pH test kit tests for pH using the Octa-Slide 2 Comparator ranging from 6.8 - 8.2 pH.

    pH Indicator: Phenol Red Standard Values in pH Units: 6.8 7.0 7.2 7.4 7.6 7.8 8.0 8.2

  • pH Test Kit 7.2 - 8.6 pH

    Order Code 2111-01

    This kit tests for pH using the Octa-Slide 2 Comparator ranging from 7.2 - 8.6 pH.

    pH Indicator: Cresol Red Standard Values in pH Units: 7.2 7.4 7.6 7.8 8.0 8.2 8.4 8.6

  • pH Test Kit 8.0 - 9.4 pH

    Order Code 2112-01

    This pH test kit tests for pH using the Octa-Slide 2 Comparator ranging from 8.0 - 9.4 pH.

    pH Indicator: Thymol Blue Standard Values in pH Units: 8.0 8.2 8.4 8.6 8.8 9.0 9.2 9.4

  • Wide Range Alkaline pH Test Kit

    Order Code 2124-01

    The LaMotte Wide Range Alkaline pH test kit tests alkaline pH levels ranging from 8.5 - 12.0 using the Octa-Slide 2 Comparator.

    pH Indicator: Alkaline Wide Range Standard Values in pH Units: 8.5 9.0 9.5 10.0 10.5 11.0 11.5 12.0

  • Precision pH Test Kit

    Order Code 5858-01

    This kit tests for pH using the Octa-Slide 2 Comparator. Covers a wide pH range from 3.0 - 10.5 pH

    Test System: Octa-Slide 2 Comparator

    Range/Sensitivity: Wide Range pH Octa-Slide 2 Bar, 3.0-6.5 Wide Range pH Octa-Slide 2 Bar, 7.0-10.5 No. of tests: 50

  • Phosphate Test Kit

    Order Code 3114-02

    This kit tests for Phosphate using the Octa-Slide 2 Comparator. Range and sensitivity is 0.5, 1, 2, 3, 4, 6, 8, 10 ppm and 5, 10, 20, 30, 40, 60, 80, 100 ppm PO43-

    Test System: Octa-Slide 2 Comparator Range/Sensitivity: 0.5, 1, 2, 3, 4, 6, 8, 10 ppm 5, 10, 20, 30, 40, 60, 80, 100 ppm PO43 No. of tests: 50

  • Low Range Phosphate Test Kit

    Order Code 3121-02

    This LaMotte Phosphate test kit tests for low range Phosphate using the LRC Comparator. Range and sensitivity is 0, 0.2, 0.4, 0.6, 0.8, 1.0, 1.5, 2.0 ppm PO43-.

    Test System: Ascorbic Acid Octet Comparator with Axial Reader Range/Sensitivity: 0, 0.2, 0.4, 0.6, 0.8, 1.0, 1.5, 2.0 ppm PO43 No. of tests: 50

  • Phosphate Colorimeter Test Kit

    Order Code 3679-01

    This Phosphate Colorimeter Test Kit test kit measures phosphate using the 1200 Colorimeter. Range is 0 to 3.0 ppm Orthophosphate (Range can be extended by dilution).

    Test Method (#of Reagents) Ascorbic Acid (2) Range (ppm) 0-3.0

  • Phosphate Test Kit

    Order Code 4401-02

    This kit tests for Phosphate using the Octa-Slide 2 Comparator. Range is 10, 20, 30, 40, 50, 60, 70, 80 ppm PO43-.

    Test System: Vanadate Molybdate Octa-Slide 2 Range/Sensitivity: 10, 20, 30, 40, 50, 60, 70, 80 ppm PO43 No. of tests: 50

  • Dual Range Phosphate Test Kit

    Order Code 7068-01

    This kit tests for Phosphate using the Octa-Slide 2 Comparator. Low range: 1.0, 2.0, 3.0, 4.0, 5.0, 6.0, 8.0, 10.0 ppm PO43- , High range : 10, 20, 30, 40, 50, 60, 80, 100 ppm PO43-.

    Test System: Octa-Slide 2 Comparator

    Range/Sensitivity: Low: 1.0, 2.0, 3.0, 4.0, 5.0, 6.0, 8.0, 10.0 ppm PO43- High: 10, 20, 30, 40, 50, 60, 80, 100 ppm PO43- No. of tests: 50

  • Low Range Phosphate Test Kit

    Order Code 7416-02

    This kit tests for Phosphate using the LRC Comparator. Range and sensitivity is 0.05, 0.1, 0.2, 0.3, 0.4, 0.6, 0.8, 1.0 ppm PO43-.

    Test System: LRC Comparator Range/Sensitivity: Low: .05, 0.1, 0.2, 0.3, 0.4, 0.6, 0.8, 1.0 ppm PO43 No. of tests: 50

  • Phosphonate Test Kit

    Order Code 7625-01

    This kit tests for Phosphonate using the drop count method. Range: 1 drop = 1.25 ppm HEDP, 1 drop = 1.4 ppm PBTC.

    Test System: CAS Dropper Pipet Range/Sensitivity: 1 drop = 1.25 ppm HEDP 1 drop = 1.4 ppm PBTC No. of tests: 50 at 20 ppm

  • Phosphonate Test Kit

    Order Code 7530-DR-01

    This kit tests for Phosphonate using the Direct Reading Titrator. Range and Sensitivity is 0-20 ppm/0.4 ppm NaAMP

    Test System: XO Direct Reading Titrator Range/Sensitivity: 0-20 ppm/0.4 ppm NaAMP No. of tests: 50 at 20 ppm

  • Phosphonate Test Kit

    Order Code 7530-WT

    tests for Phosphonate using the drop count method. Range and Sensitivity is 1 drop = 1 ppm NaAMP

    Test System: XO Dropper Bottle
    Range/Sensitivity: 1 drop = 1 ppm NaAMP No. of tests: 50 at 20 ppm

  • Phosphonate Test Kit

    Order Code 4068-01

    This kit tests for Phosphonate using the Direct Reading Titrator. Range and Sensitivity is 0-10 ppm/0.2 ppm

    Test System: XO Direct Reading Titrator Range/Sensitivity: 0-10 ppm/0.2 ppm No. of tests: 50

  • Polyphosphate Test Kit

    Order Code 7340-R-01

    This kit tests for Polyphosphate using the LRC Comparator. Range and Sensitivity is 0, 3, 6, 9, 12, 15 ppm Polyphosphate.

    A colorimetric method is available for waters where metal interference is unlikely. An excess of iron is added to the solution containing polyphosphate. The iron is complexed and the remaining iron is determined. The polyphosphate concentration is derived from the iron concentration.

  • Polyquat Test Kit

    Order Code 7056-01

    The test is based on the reaction of the cationic polyquat with an anionic polyelectrolyte using Toluidine Blue O as the indicator. The color change is blue to purple. Levels are determined using the drop count method. Range and Sensitivity is 1 drop = 1 ppm Polyquat.

    Test System: Dropper Bottle Range/Sensitivity: 1 drop = 1 ppm Polyquat No. of tests: 100+

  • Potassium Test Kit

    Order Code 3138-01

    This PotassiumTest Kit tests for potassium using a turbidity reading tube. Range and sensitivity is 6, 8, 10, 20, 30, 40, 50 ppm K+.

    Sodium tetraphenylboron reacts with potassium to form a white precipitate. The turbidity of the solution is proportional to potassium concentration which is measured in a calibrated tube.

    Test System: Turbidity Reading Tube Range/Sensitivity: 6, 8, 10, 20, 30, 40, 50 ppm K+ No. of tests: 100

  • QAC Test Kit

    Order Code 3043-DR-01

    This kit tests for QAC using the Direct Reading Titrator method. Range and sensitivity is 0-500 ppm/10 ppm Alkyl dimethyl benzyl ammonium chloride.

    A masked bromphenol blue indicator is added to the sample and turns green. Sodium tetraphenylboron is added to complex the QAC and the color changes to red. This method is best suited to higher QAC concentrations.

    Test System: BPB Direct Reading Titrator Range/Sensitivity: 0-500 ppm/10 ppm Alkyl dimethyl benzyl ammonium chloride No. of tests: 50 at 500 ppm

  • Salinity Test Kit

    Order Code 7459-02

    This Salinity kit test for salinity using the Direct Reading Titrator method. Range and sensitivity is 0-40 ppt/0.4 ppt Salinity.

    Test System: Direct Reading Titrator Range/Sensitivity: 0-40 ppt/0.4 ppt Salinity No. of tests: 50 @ 20ppt

  • Silica Test Kit

    Order Code 4463-01

    This kit tests for Silica using the Octa-Slide 2 Comparator. Range and sensitivity is 0.5, 1.0, 2.0, 3.0, 4.0, 6.0, 8.0, 10.0 ppm or 5, 10, 20, 30, 40, 60, 80, 100 ppm SiO2

    Test System: Octa-Slide 2 Comparator Range/Sensitivity: 0.5, 1.0, 2.0, 3.0, 4.0, 6.0, 8.0, 10.0 ppm or 5, 10, 20, 30, 40, 60, 80, 100 ppm SiO2 No. of tests: 50

  • Sodium Hydroxide Test Kit

    Order Code 7516-DR-02

    In this Sodium Hydroxide Test Kit a sample is reacted with barium to precipitate any carbonates, then is titrated with a standard acid to the phenolphthalein endpoint. Range/sensitivity is 0-10%/0.2% NaOH

    Test System: Direct Reading Titrator Range/Sensitivity: 0-10%/0.2% NaOH No. of tests: 50 at 10%

  • Sodium Molybdate Test Kit

    Order Code 6628-01

    This Sodium Molybdate test kit tests for molybdate using xanthate and the Octa-Slide 2 Comparator. Range/sensitivity is 1, 2, 3, 4, 5, 6, 8, 10 ppm sodium molybdate.

    Test System: Xanthate, Sodium Molybdate Octa-Slide 2 Comparator Range/Sensitivity: 1, 2, 3, 4, 5, 6, 8, 10 ppm Sodium Molybdate No. of tests: 100

  • Sodium Nitrite Test Kit

    Order Code 3036-DR-02

    This kit tests for Sodium Nitrite using the Direct Reading Titrator method. Range/sensitivity is 0-1000 ppm/20 ppm NaNO2

    Test System: CAN Direct Reading Titrator Range/Sensitivity: 0-1000 ppm/20 ppm NaNO2 No. of tests: 50 at 1000 ppm

  • Sulfide Test Kit

    Order Code 4630

    This kit tests for Total Sulfide, Dissolved Sulfide and Hydrogen Sulfide using the drop count method. Range and sensitivity is 1 drop = 1.0 or 0.1 ppm S2- or H2S

    Test System: Total, Dissolved & Hydrogen Sulfide Dropper Pipet Range/Sensitivity: 1 drop = 1.0 or 0.1 ppm S2- or H2S No. of tests: 70 at 10 ppm

  • Tannin / Lignin Test Kit

    Order Code 7831-01

    This kit tests for Tannin/Lignin using the Octa-Slide 2 Comparator. Range and sensitivity is 1, 2, 3, 4, 5, 6, 8, 10 ppm Tannin or lignin like substances.

    Test System: Octa-Slide 2 Comparator Range/Sensitivity: 1, 2, 3, 4, 5, 6, 8, 10 ppm Tannin or lignin like substances No. of tests: 50

  • Tolcide PS Biocides Test Kit

    Order Code 4-8776-01

    A kit from Solvay for the determination of for the determination of tetrakishydroxymethyl phosphonium sulfate (THPS). The iodometric titration may be used for fresh or salt water in oilfields, towers, pulp and paper, etc.

    Test System: Direct Reading Titrator Range/Sensitivity: 0-100/2 ppm THPS No. of tests: 60

  • Total Dissolved Solids Test Kit

    Order Code 4801-DR-01

    This kit tests for Total Dissolved Solids using the Direct Reading Titrator method. Range and sensitivity is 0-2000 ppm/20 ppm CaCO3.

    The procedure involves 2 acid-base titrations. The first is a direct titration of the negative ions. The second is a titration of positive ions after all positive ions have been exchanged for hydrogen in an ion exchange column. The sum of the titration results equals ppm TDS as CaCO3.

    Test System: Direct Reading Titrator Range/Sensitivity: 0-2000 ppm/20 ppm CaCO3 No. of tests: 50 at 2000 ppm

  • Turbidity Test Kit

    Order Code 7519-01

    This kit tests for Turbidity using the drop count method. Range and sensitivity is 5-100 JTU/5 JTU, 10-200 JTU/10 JTU.

    Test System: Dropper Pipet Range/Sensitivity: 5-100 JTU/5 JTU, 10-200 JTU/10 JTU No. of tests: 50 at 10 or 20 JTU

  • Zinc Test Kit

    Order Code 7391-02

    This kit tests for Zinc using the Octa-Slide 2 Comparator. Range and sensitivity is 0, 1, 2, 3, 4, 6, 8, 10 ppm Zn.

    Test System: Octa-Slide 2 Range/Sensitivity: 0, 1, 2, 3, 4, 6, 8, 10 ppm Zn No. of tests: 50

  • Zinc Test Kit

    Order Code 7417-02

    This kit tests for Zinc using the Octa-Slide 2 Comparator. Range and sensitivity is 0, 0.2, 0.4, 0.6, 0.8, 1.0, 1.2, 1.4 ppm Zn

    Test System: Octa-Slide 2 Range/Sensitivity: 0, 0.2, 0.4, 0.6, 0.8, 1.0, 1.2, 1.4 ppm Zn No. of tests: 50

  • DUOTEST double zone pH-papers

    Order Code 90303

    These indicator papers show two different colors for each pH-value at intervals of 0.3 – 1 pH-unit. This allows more accurate reading and good estimation of intermediate values.

    Range: pH 3.5 - 6.8 3.5 · 3.8 · 4.1 · 4.4 · 4.7 · 5.0 · 5.3 · 5.6 · 5.9 · 6.2 · 6.5 · 6.8

  • DUOTEST double zone pH-papers

    Order Code 90304

    These indicator papers show two different colors for each pH-value at intervals of 0.3 – 1 pH-unit. This allows more accurate reading and good estimation of intermediate values.

    Range: pH 5.0 - 8.0 5,0 · 5,3 · 5,6 · 5,9 · 6,2 · 6,5 · 6,8 · 7,1 · 7,4 · 7,7 · 8,0

  • pH-Fix test strips 0 - 14

    Order Code 92110

    Brilliant colours for exact results pH-Fix test strips feature up to four different indicator pads to cover the complete pH range. The color chart exactly matches both color and position of the pads on the strips. This enables highly precise pH determination and makes the test strips rapid and reliable.

    Range: pH-Fix 0 - 14 1 · 2 · 3 · 4 · 5 · 6 · 7 · 8 · 9 · 10 · 11 · 12 · 13 · 14

  • pH-Fix 0-14 PT

    Order Code 92111

    Improved: Simple one-hand operation The snap cap of the tube can be opened and closed just with the thumb of the holding hand. This makes working with pH-Fix 0-14 PT comfortable and relaxing.

    Range: pH-Fix 0 - 14 PT 1 · 2 · 3 · 4 · 5 · 6 · 7 · 8 · 9 · 10 · 11 · 12 · 13 · 14

  • pH-Fix test strips 7.0 - 14.0

    Order Code 92125

    Always ready for use pH-Fix test strips are used for rapid pH testing directly at the point of interest. They are always ready for immediate use. Coming with a complete color chart the test strips are already calibrated. As single use devices they are completely maintenance free. For careful testing of dangerous, poisonous or aggressive liquids the strips have the optimal design. The longest available handle effectively protects the user from contact with the sample. This increases the safety of operation and adds handling ease.

    Patented technology for optimal sample protection In the production the indicator reacts with the paper of the test pad to form a chemical bond. The dye is fixed to the test strip and can not bleed into the sample. This protects the sample against contamination and enables measurements in weakly buffered or strongly alkaline solutions.

    Brilliant colours for exact results pH-Fix test strips feature up to four different indicator pads to cover the complete pH range. The color chart exactly matches both color and position of the pads on the strips. This enables highly precise pH determination and makes the test strips rapid and reliable.

    Range: pH-Fix 7.0 - 14.0 7.0 · 7.5 · 8.0 · 8.5 · 9.0 · 9.5 · 10.0 · 10.5 · 11.0 · 11.5 · 12.0 · 12.5 · 13.0 · 13.5 · 14.0

  • pH-Fix test strips 4.5 - 10.0

    Order Code 92120

    Always ready for use pH-Fix test strips are used for rapid pH testing directly at the point of interest. They are always ready for immediate use. Coming with a complete color chart the test strips are already calibrated. As single use devices they are completely maintenance free. For careful testing of dangerous, poisonous or aggressive liquids the strips have the optimal design. The longest available handle effectively protects the user from contact with the sample. This increases the safety of operation and adds handling ease.

    Patented technology for optimal sample protection In the production the indicator reacts with the paper of the test pad to form a chemical bond. The dye is fixed to the test strip and can not bleed into the sample. This protects the sample against contamination and enables measurements in weakly buffered or strongly alkaline solutions.

    Brilliant colours for exact results pH-Fix test strips feature up to four different indicator pads to cover the complete pH range. The color chart exactly matches both color and position of the pads on the strips. This enables highly precise pH determination and makes the test strips rapid and reliable.

    Range:pH-Fix 4.5 - 10.0 4.5 · 5.0 · 5.5 · 6.0 · 6.5 · 7.0 · 7.5 · 8.0 · 8.5 · 9.0 · 9.5 · 10.0